Water Testing
10 products
Browse 10 Water Testing models from Labomiz Scientific, organised into 10 product families. Open any model for full specifications, download its catalog, or request a quotation. Tick up to four products to compare them side by side.
Water Testing types
All Water Testing models
Benchtop Digital pH Meter MBDPM-1A
| pH measurement range | -1.00 to 15.00 pH |
| pH accuracy | ± 0.01 pH |
| pH resolution | 0.01 pH |
| Calibration points | 1-3 points |
Benchtop Dissolved Oxygen Meter MBDOM-1A
| Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
| Dissolved oxygen accuracy | ± 0.2 mg / L |
| Resolution | 0.01 mg / L |
| Calibration points | 1 - 2 points |
Portable Conductivity Meter MPCM-1A
| Conductivity | Conductivity measurement range "0.01 to 20.00 200.0 2000 µS/cm 20.00 200 mS/cm" Conductivity accuracy ±0.5% F.S Conductivity calibration points 1 to 3 points Conductivity calibration solutions "10 µS/cm 84 µS/cm 1413 µS/cm 12.88 mS/cm 111.8 mS/cm or Custom" Conductivity resolution "0.001 0.01 0.1 1" |
| Temperature | Temperature measuring range "0 105 °C 32 to 221 °F" Temperature measuring accuracy "± °0.5 C ± 0.9 °F" Temperature calibration points 1 point Temperature resolution "0.1 °C 0.1 °F" |
| Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
| Temperature coefficient | Linear |
Portable Dissolved Oxygen Meter MPDOM-1A
| Dissolved oxygen range | 0.0 - 20.0 mg / L (or ppm) |
| Dissolved oxygen accuracy | ± 0.2 mg / L |
| Resolution | 0.01 mg / L |
| Calibration points | 1 - 2 points |
Portable pH and Conductivity Meter MPPCM-1A
| pH mode | pH measurement range (-2.000) to 20.000 pH pH accuracy ± 0.002 pH pH calibration points 1 - 5 points pH calibration solutions USA, NIST, DIN or user defined |
| ORP measurement | ORP measurement range -1999.9 to 1999.9 mV ORP accuracy ±0.2 mV ORP calibration points 1 point ORP calibration solutions mV & relative mV |
| Conductivity measurement | Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm Conductivity accuracy ± 0.5 % F.S. Conductivity calibration points 1 - 5 points Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm Temperature coefficient 0.0 to 10.0 % / °C Compensation modes Linear or pre water Cell constant K = 0.1, 1, 10 or user-defined Normalization temperature 20 °C or 25 °C |
| TDS measurement | TDS range 0-100 ppt. (max. 200 ppt., depending on factor setting) TDS accuracy ± 1 % F.S. TDS factor 0.1 - 1.0 (default 0.5) |
Portable pH meter MPPM-1A
| pH measurement range | pH range: (-1.00) to 15.00 pH |
| Shape of electrode | Round glass pH electrode |
| pH measurement accuracy | ± 0.01 pH |
| Calibration point | 1 - 3 points |
Portable Salinity Meter MPSM-1A
| Salinity measurement range | 0.00 to 80.00 ppt |
| Salinity accuracy | ± 1 % F.S |
| Conductivity range | 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm |
| Calibration solutions | 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm |
Portable TDS meter MPTDSM-1A
| Conductivity | Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm Conductivity accuracy ±0.5% F.S Conductivity calibration points 1 to 5 points Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom Conductivity resolution 0.001, 0.01, 0.1, 1 |
| TDS | TDS range 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) TDS accuracy ±1 % F.S TDS factor 0.01 to 1.00 (Default 0.5) TDS resolution 0.01, 0.1, 1 |
| Temperature | Temperature measuring range 0 105 °C, 32 to 221 °F Temperature measuring accuracy ± °0.5 C, ± 0.9 °F Temperature calibration points 1 point Temperature resolution 0.1 °C, 0.1 °F |
| Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
Portable Turbidity Meter MPTM-1A
| Range | 0~1100 NTU, 0~275 EBC, 0~9999 ASBC |
| Resolution | 0.01 (0~99 NTU), 0.1 (100~999 NTU), 1 (1000~1100 NTU) |
| Accuracy | ±2% of reading (0~500 NTU), ±3% of reading (501~1100 NTU) |
| Calibration Points | 2 to 5 points |
Benchtop Conductivity Meter MBCM-1A
| Conductivity | Range: 0.01~20.00, 200.0, 2000μS/cm, 20.00, 200.0mS/cm Resolution: 0.001, 0.01, 0.1, 1 Accuracy: ±0.5% F.S. Calibration Points: 1 to 5 points Calibration Solutions: 10μS/cm, 84μS/cm, 1413μS/cm, 12.88mS/cm, 111.8mS/cm |
| TDS | Range: 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt Resolution: 0.01, 0.1, 1 Accuracy: ±1% F.S. TDS Factor: 0.1~1.0 (default 0.5) |
| Salinity | Range: 0.00~42.00psu, 0.00~80.00ppt Resolution: 0.01 Accuracy: ±1% F.S. |
| Resistivity | Range: 0.00~20.00MΩ Resolution: 0.01 Accuracy: ±1% F.S. |