Centrifuges
73 products
Browse 73 Centrifuges models from Labomiz Scientific, organised into 9 product families. Open any model for full specifications, download its catalog, or request a quotation. Tick up to four products to compare them side by side.
Centrifuges types
All Centrifuges models
Blood ID centrifuge MBLC-1A
| Speed range | 4000 rpm |
| Maximum RCF | 1790 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 99 mins |
Decanting low speed centrifuge MDLC-1A
| Type | Chest |
| Max speed | 4000 rpm |
| Max RCF | 3184 x g |
| Rotor capacity | 124 x Vacuum blood tubes |
Decanting low speed centrifuge MDLC-1B
| Type | Upright |
| Max speed | 4000 rpm |
| Max RCF | 3184 x g |
| Rotor capacity | 124 x Vacuum blood tubes |
Decanting low speed centrifuge MDLC-1C
| Type | Chest |
| Max speed | 4000 rpm |
| Max RCF | 3184 x g |
| Rotor capacity | 148 x Vacuum blood tubes |
Decanting low speed centrifuge MDLC-1D
| Type | Upright |
| Max speed | 4000 rpm |
| Max RCF | 3184 x g |
| Rotor capacity | 148 x Vacuum blood tubes |
High speed centrifuge MHSC-2A
| Max speed | 18000 rpm |
| Max RCF | 23846 x g |
| Speed accuracy | ± 100 rpm |
| Noise | ≤ 55 dB |
High speed centrifuge MHSC-2B
| Max speed | 21000 rpm |
| Max RCF | 23194 x g |
| Speed accuracy | ± 100 rpm |
| Noise | ≤ 55 dB |
High Speed Centrifuge MHSC-3A
| Max speed | 18000 rpm |
| Max RCF | 23198 x g |
| Max capacity | 12 x 1.5 ml/ 2.2 ml |
| Speed accuracy | ≤ 100 rpm |
High speed centrifuge MHSC-3B
| Max speed | 14000 rpm |
| Max RCF | 17465 x g |
| Max capacity | 24 x 2 ml |
| Speed accuracy | ≤ 100 rpm |
High speed centrifuge MHSC-4A
| Max speed | 6000 rpm |
| Max RCF | 1248 x g |
| Max capacity | 2 x 8 x 0.2 ml |
| Noise | ≤ 48 dB |
High speed centrifuge MHSC-4B
| Max speed | 10000 rpm |
| Max RCF | 6596 x g |
| Max capacity | 12 x 1.5/0.5/0.2 ml |
| Noise | ≤ 48 dB |
High speed centrifuge MHSC-4C
| Max speed | 12000 rpm |
| Max RCF | 7567 x g |
| Max capacity | 6 x 1.5/0.5/0.2ml |
| Noise | ≤ 48 dB |
High speed centrifuge MHSC-5A
| Max speed | 16500 rpm |
| Max RCF | 18110 x g |
| Max capacity | 10 x 5 mL |
| Speed accuracy | ≤ 20 rpm |
High speed centrifuge MHSC-5B
| Max speed | 16500 rpm |
| Max RCF | 18110 x g |
| Max capacity | 8 x 7 mL |
| Speed accuracy | ≤ 10 rpm |
High speed centrifuge MHSC-5C
| Max speed | 16500 rpm |
| Max RCF | 18110 x g |
| Max capacity | 8 x 10 mL |
| Speed accuracy | ≤ 20 rpm |
High speed centrifuge MHSC-5D
| Max speed | 16500 rpm |
| Max RCF | 18110 x g |
| Max capacity | 24 x 1.5 mL/ 2.2 mL |
| Speed accuracy | ≤ 20 rpm |
High speed refrigerated centrifuge MHRC-1A
| Speed range | 16000 rpm |
| Maximum RCF | 18800 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 99 mins |
High speed refrigerated centrifuge MHRC-1B
| Speed range | 16500 rpm |
| Maximum RCF | 18360 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1min ~ 99 mins |
High speed refrigerated centrifuge MHRC-1C
| Speed range | 18500 rpm |
| Maximum RCF | 23900 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 99 mins |
High speed refrigerated centrifuge MHRC-1D
| Speed range | 20500 rpm |
| Maximum RCF | 28200 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 99 mins |
High speed refrigerated centrifuge MHRC-1E
| Speed range | 22000 rpm |
| Maximum RCF | 32465 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 99 mins |
High speed refrigerated centrifuge MHRC-1F
| Speed range | 23000 rpm |
| Maximum RCF | 35500 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1min ~ 9 hours 99 mins |
High speed refrigerated centrifuge MHRC-1G
| Speed range | 21000 rpm |
| Maximum RCF | 47580 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 23 hrs. 59 mins |
High speed refrigerated centrifuge MHRC-1H
| Speed range | 10000 rpm |
| Maximum RCF | 18300 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 23 hrs. 59 mins |
High speed refrigerated centrifuge MHRC-2A
| Speed range | 18000 rpm |
| Maximum RCF | 23486 x g |
| Speed accuracy | ± 100 rpm |
| Time range | 1 min ~ 23 hrs. 59 mins |
High speed refrigerated centrifuge MHRC-2B
| Speed range | 18000 rpm |
| Maximum RCF | 23486 x g |
| Speed accuracy | ± 100 rpm |
| Time range | 1 min ~ 23 hrs. 59 mins |
High speed refrigerated centrifuge MHRC-2C
| Speed range | 23000 rpm |
| Maximum RCF | 33097 x g |
| Speed accuracy | ± 100 rpm |
| Time range | 1 min ~ 23 hrs. 59 mins |
High speed refrigerated centrifuge MHRC-2D
| Speed range | 23000 rpm |
| Maximum RCF | 33097 x g |
| Speed accuracy | ± 100 rpm |
| Time range | 1 min ~ 23 hrs. 59 mins |
High speed refrigerated centrifuge MHRC-2E
| Speed range | 23000 rpm |
| Maximum RCF | 33097 x g |
| Speed accuracy | ± 100 rpm |
| Time range | 1 min ~ 23 hrs. 59 mins |
High speed refrigerated centrifuge MHRC-3A
| Speed range | 16500 rpm |
| Maximum RCF | 20038 x g |
| Speed accuracy | ± 100 rpm |
| Time range | 1 min ~ 23 hrs. 59 mins |
High speed refrigerated centrifuge MHRC-3B
| Speed range | 18000 rpm |
| Maximum RCF | 23846 x g |
| Speed accuracy | ± 100 rpm |
| Time range | 1 min ~ 23 hrs. 59 mins |
High speed refrigerated centrifuge MHRC-3C
| Speed range | 23000 rpm |
| Maximum RCF | 33097 x g |
| Speed accuracy | ± 100 rpm |
| Time range | 1 min ~ 23 hrs. 59 mins |
Low speed centrifuge MLSC-1A
| Max speed | 4000 rpm |
| Max RCF | 2432 x g |
| Rotor capacity | 15 ml / 20 ml x 6 |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-1B
| Max speed | 4000 rpm |
| Max RCF | 2432 x g |
| Rotor capacity | 15 ml / 20 ml x 12 |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-1C
| Max speed | 4000 rpm |
| Max RCF | 2111 x g |
| Rotor capacity | 15 ml / 20 ml x 24 |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-1D
| Type | Benchtop |
| Max speed | 4000 rpm |
| Max RCF | 3309 x g |
| Rotor capacity | 4 x 750 ml |
Low speed centrifuge MLSC-1E
| Type | Vertical |
| Max speed | 4000 rpm |
| Max RCF | 3309 x g |
| Rotor capacity | 4 x 750 ml |
Low speed centrifuge MLSC-1F
| Max speed | 4200 rpm |
| Max RCF | 3155 x g |
| Rotor capacity | 4 x 12 x vacuum blood tube |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-1G
| Max speed | 4500 rpm |
| Max RCF | 3373 x g |
| Rotor capacity | 20 x 150 ml |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-2A
| Max speed | 6000 rpm |
| Max RCF | 5000 x g |
| Rotor capacity | 4 x 100 ml |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-2B
| Max speed | 6000 rpm |
| Max RCF | 5000 x g |
| Rotor capacity | 4 x 100 ml |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-2C
| Max speed | 6000 rpm |
| Max RCF | 5000 x g |
| Rotor capacity | 15 ml / 20 ml x 6 |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-2D
| Max speed | 6000 rpm |
| Max RCF | 5000 x g |
| Rotor capacity | 15 ml /20 ml x 6 |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-2E
| Max speed | 6000 rpm |
| Max RCF | 5000 x g |
| Rotor capacity | 4 x 250 ml |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-2F
| Max speed | 6000 rpm |
| Max RCF | 5000 x g |
| Rotor capacity | 4 x 300 ml |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-2G
| Max speed | 6000 rpm |
| Max RCF | 5000 x g |
| Rotor capacity | 8 x 100 ml |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-2H
| Max speed | 6000 rpm |
| Max RCF | 5000 x g |
| Rotor capacity | 4 x 450 ml |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-2I
| Max speed | 6000 rpm |
| Max RCF | 4830 x g |
| Rotor capacity | 12 x 15 / 20 ml |
| Temperature raise | ≤ 10 °C |
Low speed centrifuge MLSC-2J
| Max speed | 6000 rpm |
| Max RCF | 5000 x g |
| Rotor capacity | 4 x 100 ml |
| Temperature raise | ≤ 8 °C |
Low speed centrifuge MLSC-3A
| Max speed | 5000 rpm |
| Max RCF | 3175 x g |
| Rotor capacity | 2 x 10 ml(carbon fiber rotor) |
| Temperature raise | ± 10 °C |
Benchtop low speed refrigerated centrifuge MLRC-1A
| Speed range | 5000 rpm |
| Maximum RCF | 4390 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 99 mins |
Benchtop low speed refrigerated centrifuge MLRC-1B
| Speed range | 6500 rpm |
| Maximum RCF | 5190 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 99 mins |
Benchtop low speed refrigerated centrifuge MLRC-1C
| Speed range | 5500 rpm |
| Maximum RCF | 5310 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 99 mins |
Benchtop low speed refrigerated centrifuge MLRC-1D
| Speed range | 6500 rpm |
| Maximum RCF | 5310 × g |
| Speed accuracy | ± 20 rpm |
| Time range | 1 min ~ 99 mins |
Low speed refrigerated centrifuge MLRC-2A
| Type | Vertical |
| Speed range | 4000 rpm |
| Maximum RCF | 3309 x g |
| Speed accuracy | ± 10 rpm |
Low speed refrigerated centrifuge MLRC-2B
| Type | Vertical |
| Speed range | 4200 rpm |
| Maximum RCF | 3387 x g |
| Speed accuracy | ± 10 rpm |
Low speed refrigerated centrifuge MLRC-2C
| Type | Vertical |
| Speed range | 4200 rpm |
| Maximum RCF | 4657 x g |
| Speed accuracy | ± 10 rpm |
Low speed refrigerated centrifuge MLRC-2D
| Type | Vertical |
| Speed range | 4200 rpm |
| Maximum RCF | 5116 x g |
| Speed accuracy | ± 10 rpm |
Low speed refrigerated centrifuge MLRC-2E
| Type | Benchtop |
| Speed range | 4500 rpm |
| Maximum RCF | 3524 x g |
| Speed accuracy | ± 10 rpm |
Low speed refrigerated centrifuge MLRC-2F
| Type | Vertical |
| Speed range | 4500 rpm |
| Maximum RCF | 3524 x g |
| Speed accuracy | ± 10 rpm |
Palm centrifuge MPHC-1A
| Speed range | 10000 rpm |
| Max. RCF (Round rotor) | 2500 x g |
| Max. RCF (Strip rotor) | 2800 x g |
| Speed accuracy | ± 200 rpm |
Palm centrifuge MPHC-1B
| Speed range | 4000 rpm ~ 12000 rpm |
| Maximum RCF | 7000 x g |
| Speed accuracy | 100 rpm |
| Time range | 1 to 99 minutes |
Minicentrifuge MLM-1A
| Speed range | 5400 rpm |
| Maximum RCF | 2000 ×g |
| Speed accuracy | 5400 rpm (fixed) |
| Time range | Continuous operation |
Microcentrifuge MHM-1A
| Speed range | 500 rpm ~ 15000 rpm |
| Maximum RCF | 15100 ×g |
| Speed accuracy | ± 20 rpm |
| Time range | 30 s to 99 mins |
Clinical centrifuge MLCC-1A
| Speed range | 200 rpm ~ 4500 rpm |
| Maximum RCF | 2490 ×g |
| Speed accuracy | ± 20 rpm |
| Time range | 30 s ~ 99 mins / Continuous operation |
Hematocrit centrifuge MHHC-1A
| Speed range | 200 rpm ~ 14000 rpm |
| Maximum RCF | 18620 × g |
| Speed accuracy | ± 30 rpm |
| Time range | 30 s ~ 99 mins |
Microcentrifuge MHM-2A
| Speed range | 16000rpm |
| Maximum RCF | 19040×g |
| Max Capacity | 10x5ml |
| Speed accuracy | ± 20 rpm |
Clinical centrifuge MLCC-1B
| Max. Speed | 5000rpm |
| Speed Accuracy | ±20rpm |
| Max. Volume | 6x100ml |
| Max. RCF | 4420xg |
Mini Centrifuge MLM-2A
| Speed range | 4000 rpm |
| Maximum RCF | 990 ×g |
| Rotor Capacity | 2/1.5/0.5/0.2ml×8 0.2ml×8×4 (PCR) |
| Ambient Temperature | 23 °C |
Mini Centrifuge MLM-2B
| Speed range | 7000 rpm |
| Maximum RCF | 2910 ×g |
| Rotor Capacity | 2/1.5/0.5/0.2ml×8 0.2ml×8×4 (PCR) |
| Ambient Temperature | 23 °C |
Mini Centrifuge MLM-2C
| Speed range | 12000 rpm |
| Maximum RCF | 8550 ×g |
| Rotor Capacity | 2/1.5/0.5/0.2ml×8 0.2ml×8×4 (PCR) |
| Ambient Temperature | 23 °C |
Clinical centrifuge MLCC-1C
| Speed range | 4000 rpm |
| Max Volume | 6 × 50 ml |
| Maximum RCF | 2390 × g |
| Speed accuracy | ± 10 rpm |
Hematocrit Centrifuge MHHC-2A
| Speed range | 12000r/min |
| Maximum RCF | 15800×g |
| Max Volume | 24pcs Capillary |
| Speed accuracy | ±20r/min |